THE CASE

We recently worked on a Western Star 4900 converted from an MBE 4000 to a Detroit Diesel Series 60 — a solid upgrade with electrical integration challenges.

01 / 03

The symptoms

After the swap, everything ran fine except the fan override switch in the cab. It would not engage the fan and the ECU did not respond.

02 / 03

What we found

We had already remapped the entire engine wiring harness for the Detroit, but the fan control logic did not work. On a Series 60, fan override is an input/output (I/O) function defined in the ECM configuration. Connecting wires alone is not enough.

03 / 03

The repair

The ECM was reprogrammed to accept the override input and assign the correct fan-solenoid output. With the settings mapped using DRS (or DDRS for DDEC IV+ ECUs), the manual switch operated as expected — without jumper wires or guesswork.

✳

When you swap engines, the mechanical fit is only half the job. The control system has to be integrated too.